ZIBO QIYU AIR CONDITION ENERGY RECOVERY EQUIPMENT CO., LTD. Temos diversos tipos de trocadores de calor ar-ar, como AHU, HRV, trocadores de calor de tubo de calor, trocadores de calor rotativos, serpentina de aquecimento a vapor e resfriadores de ar de superfície.

Todos esses produtos podem ser personalizados, você só precisa me dizer suas necessidades e nós temos um software profissional de seleção de modelos, podemos ajudá-lo a escolher o modelo mais adequado.

Se você estiver interessado em nossos produtos, visite nosso site para obter mais informações.

Site:https://www.huanrexi.com

Aplicação de trocador de calor de fluxo cruzado em sistema de resfriamento evaporativo indireto de data center

The application of cross flow heat exchangers in Indirect Evaporative Cooling (IDEC) systems in data centers is mainly reflected in efficient heat exchange, reducing energy consumption, and improving data center cooling efficiency. Here are its key roles and advantages:

  1. Basic working principle
    Cross flow heat exchanger is a type of heat exchange device whose structure allows two streams of air to cross each other while maintaining physical isolation. In indirect evaporative cooling systems in data centers, it is typically used for heat exchange between cooling air and outdoor ambient air without direct mixing.
    The workflow is as follows:
    The primary air (data center return air) exchanges heat with the secondary air (external ambient air) through one side of the heat exchanger.
    The secondary air evaporates and cools in the humidification section, reducing its own temperature, and then absorbs heat in the heat exchanger to cool the primary air.
    After the primary air is cooled down, it is sent back to the data center to cool down the IT equipment.
    The secondary air is ultimately discharged outdoors without entering the interior of the data center, thus avoiding the risk of pollution.
  2. Advantages in Data Centers
    (1) Efficient and energy-saving, reducing cooling demand
    Reduce cooling load: By using cross flow heat exchangers, data centers can utilize external air cooling instead of relying on traditional mechanical refrigeration (such as compressors).
    Improve PUE (Power Usage Effectiveness): Reduce the operating time of mechanical cooling equipment, lower energy consumption, and make PUE values closer to the ideal state (below 1.2).
    (2) Completely physically isolated to avoid contamination
    Cross flow heat exchangers can ensure that outdoor air does not come into direct contact with the air inside the data center, avoiding pollution, dust, or humidity affecting IT equipment. They are suitable for data centers with high air quality requirements.
    (3) Suitable for various climatic conditions
    In dry or warm climates, indirect evaporative cooling systems are particularly effective and can significantly reduce the cooling costs of data centers.
    Even in areas with high humidity, optimizing the design of heat exchangers can improve heat exchange efficiency.
    (4) Reduce water resource consumption
    Compared to direct evaporative cooling (DEC), indirect evaporative cooling does not require direct spraying of water into the air of the data center, but rather indirect cooling through a heat exchanger, thus reducing water loss.
  3. Applicable scenarios
    Cross flow heat exchangers are widely used in the following types of data centers:
    Hyperscale Data Center: Requires efficient and energy-saving cooling solutions to reduce operating costs.
    Cloud computing data center: requires high PUE values and seeks more sustainable cooling methods.
    Edge Data Center: typically located in harsh environments, requiring efficient and low maintenance cooling systems.
  4. Challenge and Optimization Plan
    Heat exchanger size and efficiency: Larger cross flow heat exchangers can improve heat exchange efficiency, but they also increase the footprint, so optimization design is needed, such as using aluminum or composite material heat exchangers to improve heat exchange efficiency.
    Scaling and maintenance: Due to humidity changes, heat exchangers may experience scaling issues, requiring regular cleaning and the use of corrosion-resistant coatings to extend their lifespan.
    Control system optimization: Combined with intelligent control, dynamically adjust the working mode of the heat exchanger based on external environmental temperature, humidity, and data center load conditions to improve system adaptability.
  5. Future Development Trends
    New efficient heat exchange materials, such as nano coated heat exchangers, further improve heat exchange efficiency.
    Combined with AI intelligent control system, dynamically adjust the heat exchange according to the real-time load of the data center.
    Combining liquid cooling technology to further improve heat dissipation efficiency in high-density server rooms.

Cross flow heat exchangers play an important role in the indirect evaporative cooling system of data centers, providing efficient heat transfer, reducing energy consumption, minimizing pollution, and improving equipment reliability. They are currently one of the important technologies in the field of data center cooling, especially suitable for large-scale, high-efficiency data centers.

Ventilação Comercial e Recuperação de Energia

A qualidade adequada do ar interno (QAI) envolve muitos fatores, dependendo da situação local e do clima. Problemas de saúde, como problemas respiratórios, podem surgir do ar contendo poeira, pólen ou outros contaminantes. Um ambiente interno ruim também pode danificar edifícios.

Unidades de tratamento de ar comerciais (não residenciais) tendem a ser unidades maiores, projetadas para edifícios como escritórios, hotéis e aeroportos. O desafio é atingir uma qualidade do ar interno confortável com o mínimo de consumo de energia possível. Isso significa que a queda de pressão deve ser baixa (menos potência do ventilador é necessária) e a eficiência térmica/de umidade alta (menos energia consumida para aquecimento/resfriamento/controle de umidade).

Dependendo da região geográfica, o objetivo principal do trocador de calor muda entre aquecer ou resfriar (e talvez também desumidificar) o ar externo antes que ele entre no edifício.

A unidade de tratamento de ar (UTA) está no centro de um sistema de ventilação. No mínimo, uma UTA inclui um ou vários ventiladores em cada canal de ar para mover o ar através da unidade. Filtros em ambos os lados removem poeira, pólen, etc., e protegem os ventiladores. Finalmente, um trocador de calor transfere o calor ou a umidade necessários do ar de exaustão para o ar fornecido.

Implementar um trocador de calor ar-ar é uma excelente maneira de utilizar o que geralmente é considerado calor residual. Um trocador de calor ar-ar usará a diferença de temperatura entre o ar fornecido e o ar de exaustão para aumentar a eficiência do sistema. Existem dois tipos de trocadores de calor ar-ar: trocadores de calor rotativos e de placas.

O tipo e a configuração exata dependem da aplicação. Ambos os tipos são feitos de alumínio, que tem excelentes propriedades, como capacidade eficiente de transferência de calor e uma vida útil extraordinariamente longa. Oferecemos inúmeras variáveis e opções de design para cada produto, permitindo ajuste e desempenho perfeitos em cada AHU.

Resfriamento indireto em data centers

Modern data centers are remarkably technologically complex, and keeping them running safely and efficiently requires continual close monitoring and management.

Maintaining the correct temperature is among the most important tasks faced by data center managers. Should the temperature and humidity rise to excessive levels inside the data center, condensation can start forming, damaging the machines within. This can cause massive damage and disruption, so it must be avoided at all costs. Fortunately, various technologies are on hand that can help keep data center temperatures at the right level.

There are numerous ways to cool a data center. Indirect air cooling uses external air, but by including an air-to-air heat exchanger, the outside air is kept in a separate loop, providing cooling without entering the server room.

Indirect cooling methods benefit by not contaminating the inside air with outdoor air pollutants and humidity. A heat exchanger keeps both airstreams separated while transferring the heat from the inside to the outside of the data center building. Consequently, the ambient and indoor air never mix.

Dry cooling is usually sufficient if the data center is located in a consistently low-temperature area, meaning no water is involved. However, by spraying water on the ambient air side of the heat exchanger, an evaporative effect is achieved, resulting in a lower indoor air temperature. This method is called indirect evaporative cooling (IEC).

Ideally suited for warm, dry climates, IEC provides excellent cooling potential with low operational- and first-cost. Ambient temperature reductions of 6-8 °C (10-15 °F) are typical in summer conditions. IEC provides up to 28% in energy savings compared to conventional free cooling and 52% to air-cooled Free Cooling alternatives.

Evaporative cooling requires a plate heat exchanger that balances high efficiency with low pressure drop, offers solid corrosion protection, and reliable water tightness. Cross-flow heat exchangers meet all these requirements while providing outstanding cooling capacity.

Our crossflow heat exchangers, especially with evaporative cooling technology, provide an efficient, low-cost, and environmentally friendly alternative to traditional cooling methods.

Indirect Cooling in Data Centers

Um método rápido para eliminar fumaça branca

O princípio da utilização de um condensador para desumidificação e eliminação de fumaça branca baseia-se principalmente nas alterações físicas do vapor d'água nos gases de combustão. O condensador resfria os gases de combustão com água ou ar em baixa temperatura, reduzindo gradualmente sua temperatura, e o vapor d'água em seu interior começa a condensar em pequenas gotículas de água. Essas pequenas gotículas se acumulam no interior do condensador e, eventualmente, formam água líquida, que é então removida através de tubos de drenagem. A desumidificação por condensador é um meio técnico eficaz para eliminar a fumaça branca. Ela não só reduz a poluição visual, como também ajuda a melhorar a eficiência operacional e o efeito de economia de energia dos equipamentos de proteção ambiental. Podemos fornecer uma solução adequada para a desumidificação de gases de combustão, que seja econômica e ecologicamente correta. Entre em contato conosco por e-mail.

Equipamentos eficientes para remoção de gases de combustão industriais

Equipamentos industriais de dessulfurização de gases de combustão com tecnologia de troca de calor para reduzir o teor de vapor d'água nos gases de combustão, eliminando assim a pluma de fumaça branca gerada durante as emissões da chaminé. A seguir, alguns métodos comuns para branqueamento de gases de combustão:

Tecnologia de aquecimento de gases de combustão: O gás de combustão úmido dessulfurizado é trocado de calor com gases de combustão industriais de alta temperatura por meio de um trocador de calor para aumentar a temperatura de emissão dos gases de combustão, reduzindo assim a umidade relativa dos gases de combustão e evitando a condensação do vapor d'água para formar fumaça branca. Este método pode reduzir efetivamente a geração de fumaça branca, mas requer uma certa quantidade de energia para aquecê-la.

Tecnologia de condensação de gases de combustão: primeiro, condensa-se parcialmente o vapor de água nos gases de combustão saturados e, em seguida, aquece-se o gás de combustão. Este método reduz a formação de fumaça branca, diminuindo o teor de umidade dos gases de combustão, além de recuperar parte dos recursos hídricos.

Tecnologia MGGH: Instalação de trocadores de calor para resfriamento de gases de combustão antes e depois do precipitador eletrostático, instalação de trocadores de calor para aquecimento de gases de combustão após a dessulfuração e instalação de um sistema de circulação de água do meio de aquecimento. Esta tecnologia extrai o calor da fumaça original para aquecer a fumaça limpa, que geralmente precisa ser elevada a 75-80 ℃ para evitar a produção de fumaça branca.

Em resumo, cada um desses métodos apresenta vantagens e desvantagens, sendo adequados para diferentes ambientes e necessidades industriais. Ao selecionar tecnologias específicas de dessulfurização de gases de combustão, fatores como condições do processo, recursos de calor residual e requisitos de investimento devem ser considerados. Entre em contato conosco por e-mail.

Depurador de fumaça: remoção eficiente de fumaça branca com métodos físicos

O depurador de fumaça condensa o vapor d'água dos gases de combustão em líquido através de um condensador, e os poluentes gasosos aderem ao líquido condensado antes de serem descarregados pelos gases de exaustão. Essa tecnologia não requer um coletor, mas utiliza o líquido precipitado para transportar os poluentes, reduzindo assim os custos operacionais e minimizando a poluição ambiental causada pela fumaça branca.

O equipamento de remoção de fumaça branca produzido por nossa empresa possui um design compacto, instalação flexível e fácil operação, o que permite a remoção eficiente e rápida da fumaça branca gerada na produção industrial. É utilizado principalmente para dessulfuração e branqueamento de gases de combustão de caldeiras a carvão, caldeiras a gás, usinas de energia, metalurgia e outras indústrias.

Dispositivos de economia de energia para dissipação de calor em salas de informática

O núcleo de troca de calor do dispositivo de economia de energia e dissipação de calor da sala de computadores é uma solução eficiente de dissipação de calor projetada especificamente para data centers ou salas de servidores. Ao otimizar a eficiência da troca de calor, o consumo de energia pode ser reduzido e o desempenho do sistema pode ser aprimorado. O trocador de calor produzido por nossa empresa utiliza folha de alumínio hidrofílica como material de troca de calor, e a superfície foi especialmente tratada para ter excelente hidrofilicidade, o que pode promover a rápida formação e remoção de água condensada. Durante o processo de troca de calor, a camada hidrofílica pode efetivamente aumentar a área de troca de calor e melhorar a eficiência da troca de calor. A adoção de um design de microcanais multicamadas aumenta a área de contato entre o fluido e a parede metálica, melhorando assim a eficiência da transferência de calor. Melhorou significativamente a taxa de eficiência energética dos data centers e reduziu os custos operacionais.

Tecnologia de recuperação de calor para sistemas de ar condicionado em shoppings

Na busca atual por uma experiência de compra de alta qualidade, não nos concentramos apenas na riqueza e diversidade de produtos, mas também nos preocupamos com o conforto e a sustentabilidade do ambiente de compras.
O cerne da tecnologia de recuperação de calor do sistema de ar condicionado da nossa empresa reside na combinação perfeita entre o design do trocador de calor de alta eficiência e o sistema de controle inteligente. Ele pode coletar com eficiência o calor residual gerado durante a operação do ar condicionado e convertê-lo em energia valiosa para aquecimento no inverno, água quente sanitária e até mesmo pré-resfriamento de ar fresco em shoppings.
Este processo não requer consumo adicional de energia e permite a reciclagem interna de energia, reduzindo significativamente o custo total de consumo de energia do shopping. Além disso, pode ajustar automaticamente o status operacional e a intensidade da recuperação de calor do ar-condicionado. Isso significa que, seja no verão escaldante ou no inverno frio, o shopping pode garantir temperatura e umidade constantes, proporcionando aos clientes o ambiente de compras mais confortável e, ao mesmo tempo, alcançando o melhor efeito de economia de energia. Sinta-se à vontade para nos contatar por e-mail.

Esquema de economia de energia para recuperação de calor do sistema de ar condicionado central

Na operação de sistemas de ar condicionado central, podemos adotar trocadores de calor de alta eficiência para planos de renovação com economia de energia, e podemos escolher trocadores de calor de placas ou trocadores de calor de microcanais com alta eficiência de transferência de calor e baixa resistência a fluidos. Nosso trocador de calor possui uma área de transferência de calor maior e um desempenho de transferência de calor mais eficiente, o que pode reduzir o consumo de energia sob as mesmas condições de transferência de calor. Instale um dispositivo de recuperação de calor residual no sistema de ar condicionado central para recuperar e reutilizar o calor emitido. Ele também pode ser combinado com a tecnologia de bomba de calor, que é uma maneira eficiente de transferir energia térmica consumindo uma pequena quantidade de eletricidade ou energia de combustível para transferir o calor de uma fonte de calor de baixa temperatura para uma fonte de calor de alta temperatura. A aplicação da tecnologia de bomba de calor em sistemas de ar condicionado central pode melhorar o coeficiente de desempenho (COP) do sistema e reduzir o consumo de energia.